Transformer Turn Ratio Tester(TTR)

Full Automatic TTR Meter Transformer Turns Ratio Tester

Full Automatic TTR Meter Transformer Turns Ratio Tester

In power transformer production, user handover and maintenance test process,transformer ratio test is the item must do, it can effectively supervise the quality of transformer and quality in using process, to prevent the transformer turn-to-turn short circuit, open circuit, connection error, regulating switch internal fault or contact failure.

Product Characteristics

Model NO.
CYZB-201A
Control
Computer Control
Weight
0-100Kg
Power Source
AC220V
Oil Cylinder Position
No Oil Cylinder
Ratio Measurement Range
1-10000
Accuracy
1-1000 0.2% 1000-10000 0.5 %;
Usage
Transformer Ratio Test
Group Test Range
1-12
Power Supply
220V±10%, 50Hz/60Hz
Phase Test Range
0-360°
Relatively Humidity
0-40ºC
Dimension
400×290×170mm3
Transport Package
Wooden Box with Wrapping Film
Specification
Can be customized
Trademark
United Electrical
Origin
Hubei, China
HS Code
9030820000

I. Product Introduction & Features:

In power transformer
 productionuser handover and maintenance test process,transformer ratio test is the item must do, it can effectively supervise the  quality of transformer and quality in using process, to prevent the transformer turn-to-turn short circuit, open circuit, connection error, regulating switch internal fault or contact failure. The automatic transformer ratio tester developed by our company according to the requirements on site, make the operation more simple, with full functional, stable and reliable data and faster test speed. Meet the requirements of  various large and small transformer tests.


1. Easy to operate.
2. Large ratio measurement: 1-10000
3.Powerful, it can test single phase, also can realize automatic test of the three-phase winding, can arbitrarily choose connection group, complete measurement of AB, BC, CA three-phase parameters such as ratio, error and connection group.
4. Quick measurement.(three phases test at same time only need 10 seconds)
5. Automatically cut off test power when one test complete.
6. Set the data, the measurement results are automatically saved, and can view the previous data.
7. Test the load transformer, only input ratio one time.
8. Easy to carry and suitable for field work.


II. Main Parameter

1.Ratio Measurement Range:1-10000
2.Accuracy:1-1000  0.2%    1000-10000  0.5%
3.Power Supply:220V±10%,50HZ/60HZ
4.Group:1-12
5.Work Temperature:0-40ºC
6.Environment:<80% Non-condensate
7.Dimension:400×290×170MM3
Company Profile

Kiyu Power is a high-tech enterprise professionally engaged in R & D, manufacture and marketing of power testing products, instruments, power industry automation systems for 20 years.We export completed set to Korea, Singapore, Vietnam, India, Ecuador, Paraguay, Pakistan, Philippines, Russia, Italy, Austria, Portugal, Chile such as PD test system, impulse voltage generator, temperature rising test system, transformer comprehensive test system, cable fault detect system and varies of instruments for transformer, circuit breaker, switchgear, lightning arrestor, insulator, cable, battery,SF6 gas and so on.